WEBWAYONE LTD, Unit 11 Kingfisher Court
Hambridge Road, Newbury, Berkshire. RG14 5SJ
00 44 1635 231 514 support@webwayone.co.uk
Risco Alarm panels
ProSys 40, ProSys 128
Applications supported
SIA alarm transmission
Remote upload/download via WebWay ATS and WebWay Remote Manager
Physical connection details
Select Dip switch 10 to ON (bottom left corner of the PCB) for a Terminated RS485 connection
Connect the A, B, and gnd terminals of the WebWayOne to connector J1 on the ProSys alarm panel. Use either the
WebWay provided cable or make to suit.
The connection details are as follows:
Bus 2 WebWayOne 2424
YEL A
GRN B
COM RTN
Connect the WebWay PWR + and - to any relevant Power and Ground terminals.
WebWayOne configuration
Environment variable settings
PANEL_TYPE = RISCO
Button menu 9, option L
Panel configuration
The following configuration stages have to be completed to add the WebWayOne to the panel.
1) Adding the ACM Module
2) Set up the ACM Module
3) Set up the Communication Path IP Addresses and Port numbers
4) Set up Account Numbers
5) Set up Alarm Format
6) Ensure Upload/Download Communication is not encrypted
7) Enable Upload/Download
8) Disable Callback on Upload/Download
9) Enable Upload/Download through GSM