Scantronic S95EN installation
The S Series main board assembly has a 9 way D-type connector at the top right. This connects to the R, T and RTN
terminals of the WebWayOne panel interface. The connection details are as follows:
9 way D-type WebWayOne 2424
2 T (Blue) 232
3 R (Red) 232
5 RTN (Green)
Connect the WebWay PWR + and - to any relevant Power and Ground terminals.
Scantronic S95EN configuration
Go to Menu 52 Digicom
Select comms format <SIA 3>
Select ARC no. <01234 567890> (any valid phone number is acceptable)
Select account No <______> (ignore account numbers 2-8)
Select dialing mode <Consecutive>
Select digicom options
Select Restore signals <enable>
Select FF channels <8 FF channels>
Select Line fault <enable>
Go to Menu 53 – RS232 options
Select RS232 option baud <38400>
Select Remote modem <enable>
Go to menu 51
Select serial number <______>
Select account name <______>
Select Access mode <unattended>
Select Edit call Nos <not configured>
Select Modem options rings to answer <immediate>
Select Baud rate <1200>
Select Downloader - Modem options - Ans Phone Defeat <Disabled>
Back to panel list