7. DCD timeout : 255
0. Back to main menu
+. Next page
-. Previous page
Make your choice:
Do the same for 7: Set value to 255 for DCD timeout. This disables DCD timeout
Select 0 to go back to main menu:
Select 1: Central Station menu
Central station menu
====================
1. Central station 1
2. Central station 2
3. Central station 3
4. Central station 4
5. Up/download menu
0. Back to main menu
Make your choice:
Select 1: Central station 1
Central station 1 menu
======================
1. Account code 1 : 1111101
2. Account code 2 : 1111102
3. Account code 3 : 1111103
4. Account code 4 : 1111104
5. Account code 5 : 1111105
6. Account code 6 : 1111106
7. Account code 7 : 1111107
8. Account code 8 : 1111108
9. Network address: 511100
0. Back to Central Station menu
Make your choice:
Select 9: Network address and make sure there are 6 or more digits. They can be any combination.
Select 0 until you are at the main menu
Select 0: Exit MPI programming and follow instructions
Turn PC-programming dip-switch 3 on to exit.
Goodbye.
Last and crucial, make sure switch 5 on the MPI232 moduke is set to OFF. This turns off callback mode.