Mk 3 SPT Serial Number 54- or 55-xxxxxx-1
Note: Jumpers should be set to RS232
Red – Any +12V Terminal at Alarm Panel
Mk 4 SPT Serial Number 56-xxxxxx-1
Red – Any +12V Terminal at Alarm Panel
Items to Check
Menu 13 – Check that a module has been selected, either 0=SMO or 1=SM1, alternatively Dialler has been selected. If
not set Menu’s 11 & 12 will not be accessable.
SPT – Make sure the parameter GUARDALL_PANEL_TIMEOUT has not been programmed, if it has, remove any values
associated.
Check the fuse on the Serial Module is operational.
If you have configured the panel for a DCM connection and despite the panel set up being correct, the panel is not dialling
out; reboot the panel.
If the GSR is not present in Menu 12; then it should appear in Menu 20.
Guardall alarm panel configuration for all ranges
Select menu 11 telephone number 1
Select Tel Number <1>
Enter Tel Number <01234 567890> (any valid phone number is acceptable)
Select Module <SM 0> This is valid for those panels which include an integrated module. For the external
modules on the legacy range you will need SM 1.
Select Assist <Off>
Select Format <Guardall>
Select Auto Test <Off>
Select Attempt <3>
Select Backup <0>
Select Call Repeat <Off>
Select GSR <1>
Select Alarm <On>
Select Set/Unset <On>
Select Bypass <On>
Select Trouble <On>
Select Log On <On>
Select Eng On <On>
Select Reset <On>
Select Restore <On>
Press X button twice