Select the jumper settings for TTL.
Connect the WebWay panel interface R, T and RTN using the supplied molex cable. This goes T- red R-Green RTN-
Blue and it plugs onto the 8 way Molex type connector labelled ‘Digi-Modem’. This is where the DC58 module would
normally be plugged in.
Connect the WebWay PWR + and - to any relevant Power and Ground terminals.
TS 690 panel Configuration:
Engineer menu 2-C Modem options
1 Callback No 1 123456
2 Callback No 2 No setting
3 Callback No 3 No setting
4 Password This must match the password configured in the Downloader application account setup
5 Modem site No This must match the site ID configured in the Downloader application account setup
6
Telephone No 1 No setting
Telephone No 2 No setting
Account No 1 No setting
Account No 2 No setting
Reports 1 No setting
Reports 2 No setting
Set/Day No setting
Restore No setting
7 Digi, Idle No setting
If you need to configure the panel type yourself:
Menu 9 option 1 PANEL = TS690
TS 790/900/2500 panel Configuration:
Engineer menu 2-C Modem options