Programming SD1+
26
Option 9: Last Call Log
Once someone has acknowledged a call, the SD1+
stores a record of the event. You can see that record
using option 9.
1. If necessary initialise the SD1+ .
SD1+
2. Key in the current passcode.
READY
3. Press 9, the display shows:
VIEWLOG-
4. Press [.
The display shows the last event recorded by the
unit. In the example shown at the right, the unit sent
message A to telephone number 3, which
acknowledged the call.
If the display shows:
A)----“ then none of the calls for message A were
acknowledged.
BLANK” then the log is empty.
A)--3-
5. Press [ to return to “READY”.
READY
SD1+ Installation
7
SD1+ SD1+
+12V +12V
TRIG POLARITY TRIG POLARITY
0V 0V
++
- -
TRIG A TRIG A
TRIG B TRIG B
TRIG C TRIG C
+12V on alarm
0V on alarm
1K
resistor
1K
resistor
N.C.
Loop
N.O.
Loop
N.O.
Loop
N.C.
Loop
TRIG A = Normally Closed Input
TRIG B = Normally Open Input
TRIG C = Switched +ve Input
TRIG A = Normally Open Input
TRIG B = Normally Closed Input
TRIG C = Switched -ve Input
CONTROL PANEL CONNECTIONS
The table below lists the connection details to various control panels.
Control Panel TRIG A TRIG B
Fire
TRIG C
PA
Polarity Supply + Supply - Trigger
Type
Menvier TS400/TS410 Zone 4 Zone 5 ALM
-
Aux + Aux - 0V app.
Menvier TS510 N/A OP 2 * OP 1 *
+
Aux + Aux - 12V app.
Menvier TS690R OP 1 OP 2 OP 3
-
Aux + Aux - 0V app.
Menvier TS690/TS700 Digi 1 Digi 2 Digi 3
-
Aux + Aux - 0V app.
Menvier TS790/TS900/TS2500 Digi 1 Digi 2 Digi 3
-
Aux+ Aux - 0V app.
A1 Advantage N/A N/A Bell -
-
Aux + Aux - 0V app.
ADE Optima XM N/A N/A B
-
13V + 13V - 0V app.
ADE Optima 2+ Fire PA Intruder
-
13V + 13V - 0V app.
ADE Concept 6 N/A N/A B
-
13V + 13V - 0V app.
ADE Accenta 6 N/A N/A B
-
13V + 13V - 0V app.
Ademco Infra 6 N/A N/A 3
+
Aux + Aux - 12V app.
Ademco Infra 16 1* 2 3
+
Aux + Aux - 12V app.
C & K 700L N/A N/A S-
-
Aux + Aux - 0V app.
CQR Premia 9 FA * PA IA
+
Aux 12V Aux 0V 12V app.
DA Abacus 6 N/A N/A Bell
-
+12V 0V 0V app.
DA Abacus 8 N/A N/A Bell
-
+12V 0V 0V app.
Gardtec 500 Series N/A N/A Bell -
-
Power + Power - 0V app.
Gardtec 800 Series D1 * PA 12Hr
-
12V 0V 0V app.
JSB Regent COM1 COM2 COM3
+
12V 0V 12V app.
Pyronix Paragon + /E N/A N/A BA
-
Aux + Aux - 0V app.
Pyronix Octagon N/A PA ALM
-
Aux + Aux - 0V app.
Pyronix Conqueror N/A N/A BA
-
Aux + Aux - 0V app.
Scantronic 9448 N/A COM 2 COM 3
-
12V 0V 5V rem.
Scantronic 9452/3 N/A COM 1 COM 3
-
Aux 12V Aux 0V 5V rem.
Scantronic 9454 N/A COM 1 COM 3
-
12V 0V 5V rem.
Scantronic 9455 N/A COM 1 COM 3
-
12V 0V 5V rem.
Texecom Veritas R8 N/A N/A B
-
Aux + Aux - 0V app.
Texecom Veritas 8 Compact N/A N/A B
-
Aux + Aux - 0V app.
* Control panel output requires programming.